Methods¶
Every model qmrust fits, grouped by method family. Each page documents what the model reads, what it produces, and how to run it with and without BIDS.
T1 Relaxometry¶
Inversion Recovery
Fits the longitudinal relaxation time T1 from a series of inversion-recovery images acquired at different inversion times.
IRT1 · T1map
Variable Flip Angle
Fits the longitudinal relaxation time T1 from spoiled gradient-echo images acquired at two or more excitation flip angles and a single repetition time.
VFA · T1map, M0map
T2 Relaxometry¶
Field Mapping¶
Actual Flip Angle B1+
Maps the transmit (B1+) field from a single spoiled gradient-echo sequence that interleaves two excitation repetition times at one nominal flip angle.
TB1AFI · TB1map
Double Angle B1+
Maps the transmit (B1+) field from two spoiled gradient-echo volumes acquired at flip angles alpha and twice alpha.
TB1DAM · TB1map
Magnetization Transfer¶
Semi-quantitative MT¶
MT Ratio
Computes the magnetization transfer ratio from two images: one acquired with an off-resonance saturation pulse and one without.
MTR · MTRmap
MT Saturation
Derives the MT saturation parameter from three spoiled gradient-echo volumes — MT-weighted, PD-weighted and T1-weighted.
MTS · MTsat, T1map, MTRmap